sumake

Digital torque meters


sumake Feature:
  • Rechargeable battery drive.
  • By the auto power OFF, it forgets to erase and prevent.
  • By the RS232C output, it is personal computer management about data.
  • One-touch zero adjustment.
  • Measured-value display automatic clear setup.
  • High and low limits judging function.
  • The maximum, the minimum, and the average can be checked.

Specification:
Model No. CD-100M CD-10M
Measure Range
(at the time of Track)
1.10~15 N-m 0.01~1.50 N-m
1.0~150 kgf-cm 0.10~15 kgf-cm
1.0~130 lbf-in 0.10~13 lbf-in
Accuracy ±0.5% (F/S) (199 or less digit ± 1 digit)
Display The 3.5 figures digital display of LCD
Measuring Direction CW- CCW (right-left)
Measuring mode: P-P (peak to Peak) The highest value of load is hold-displayed.
Measuring mode: T-R (Track) A display also changes with load change.
Measuring mode: P-D (Peak - Down) Load catches and display the moment included in descent from a rise.
High and low limits judging function High and low value are measurement within the limits and can be set up.
Real-time Output Load torque value is outputted every about 1/100 second by rs232C.
The Maximum, the minimum, and the average value display The maximum, the minimum, average value, and the data number of 30 data are displayed. It saves to ten channels.
Automatic Clear time In 1.0-3.0 seconds (0.5-second interval, an indication is automatically given zero.)
It is a manual zero clearance by 0.0-second setup.
One-touch zero By pushing a clear button, zero adjustment can be performed by one-touch.
Data memory / Data output 300 data / RS232C conformity (baud rate 9600)
Power supply Nickel-cadmium battery 1.2V 5 cells (700mAh).
Auto power save Power-supply OFF is carried out after the neglect during 10 minutes.
Charge time / use time At the time of charge 6 hour / maximum charge Continuation about 12-hour use.
Battery life 300 times or more charge.
Socket size 20mm x 20mm & 9.5mm x 9.5mm
Weight 1kg
Accessories (one piece each) Measurement join SJ50/SJ10
(4 bits HEX Opposite side 6mm)
Measurement join SJ10
(4 bits HEX Opposite side 6mm)
RS-232C connector cable*1, drive on CD-ROM*1 (for windows)
M4 screw*4, transfer bit*4 M4 screw*2, transfer bit*2
Exclusive case
AC / DC adaptor (Choose AC adaptor out of 120V, and 230V)
Result of calibration, certification on calibration, traceability system figure.
SJ50 SJ10(K)
sumake sumake
Model No. Range
( kgf-cm )
1.0~150 kgf-cm 0.10~15 kgf-cm
SJ015(optional) 0.2~2.5
SJ10 1.5~10.0
SJ50 5.0~50.0
SJ100(optional) 50.0~100.0
About an adapter
[ measurement join SJ(PAT.P)]
It does not decompose, even if it rewind join too much.
Adapter attached is the coil spring compression system of the conventional system, you can use it by the conventional management method.
Moreover, this adapter is special structure. It does not decompose, even if it rewinds joint too much. You can use it in comfort.